How to fit an automatic bypass valve and why you might need one

If your boiler does not have constant flow across it and you have thermostatic radiator valves fitted then here is the answer. We only have a handwheel bypass valve How do we establish whether this is open/closed to the correct degree and which way does one turn it o close/open How does this fit in with balancing the radiators Building regulations requirements government approved guidance covering the part of the building regulations related to the conservation of energy states that in all systems in which the boiler manufacturer’s instructions demand a bypass, or specify a minimum flow rate through the boiler, that an automatic bypass valve be fitted This type of valve modulates open when necessary to ensure.

Sorry if this sounds silly but how do you know what setting to set an automatic bypass valve at The valve is fitted just after the pump and just after the last return tee (from the hot water cylinder) I have a vaillant ecotec pure 830.i want to fit in an auto bypass valve in case the pump continues to work after my zone valves are closed Which setting on the bypass valve do i need to set It has the following setting. Typically set the auto bypass to 0.2 bar

There are many web sites suggesting how to set them more closely to suit any particular system where the objective is to set them to just start flowing when 2/3 of the trvs are off

I'll try this value, thanks. I want to understand how the turning of an automatic bypass valve knob is meant to work to determine if mine is weird Our actual plumber recently installed an auto bypass valve to our central heating system Previously it had a gate valve He set up the bypass valve to. Central heating advice on installing a bypass valve on central heating flow/return

However, i don't even know if these changes are possible or permissible Our system consists of a worcester 24i junior (2006 model) combi boiler and 5 radiators (4.